WYH series poultry house heating hot air stove (click to enter)
WMHChicken coop composite hot air stove
Compound heating: using two methods of tube heating: flue gas and hot air. Both methods consume all the heat50%about. This unique heating technology combines the advantages of two heating methods.
Smoke duct: The length starts from the furnace and runs through the entire chicken coop. Set in the span of the chicken coop1/4—1/3The location. Center height of flueone point fiveMeter, diameterthree hundredMade of zinc sheet.
Air duct: length from the furnace to the back of the chicken coop5-10Mi, set in the middle of the chicken coop span or slightly towards the other end. The height of the air duct is generally within1.8-2.5Between meters. diameterfour hundredfrontfifteenRice is made of zinc plates. The back is made of canvas. both sidesone hundred and twentyThe downward angle of the air outlet is staggered and dispersed.
Main technical parameters
model | Rated heat generationkj/h | Hot air volumeM3/h | Heating areaM2 | Air outlet temperature Celsius | Overall thermal efficiency% | Rated coal consumptionKg/h | Experienced coal consumptionKg/g | Fan power introduction+Hoodkw |
WMH30 | one million two hundred and fifty-five thousand | eight thousand | one thousand and four hundred | one hundred and fifty | 》95% | forty-two | twelve | 3+0.75 |
WMH40 | one million six hundred and seventy-two thousand | ten thousand | one thousand and eight hundred | one hundred and fifty | 》95% | fifty-eight | fifteen | 4+0.75 |
Note:oneThe rated coal consumption refers to the theoretical amount of coal required to reach the rated heat generation.
twoThe experience of coal consumption refers to the use of standardized insulation, raising commercial chickens, rice husks for flat farming, and outdoors-15Celsius degrees1-3The chick rearing area has reachedthirty-fivecentigrade. Breeding periodforty-fiveThe hourly average coal consumption of the entire batch of chickens in the day.
WMHDual air self-control energy-saving hot blast stove
Main technical parameters
model | Rated heat generationkj/h | Hot air volumeM3/h | Heating areaM2 | Air outlet temperature Celsius | Overall thermal efficiency% | Rated coal consumptionKg/h | Experienced coal consumptionKg/g | Fan power introduction+Hoodkw |
WMH10 | four hundred and eighteen thousand | three thousand and eight hundred | five hundred | one hundred and fifty | 》90% | fifteen | five | two |
WMH15 | six hundred and twenty-seven thousand | five thousand and six hundred | seven hundred and fifty | one hundred and fifty | 》90% | twenty-two | nine | 1.5x2+0.55 |
WMH20 | eight hundred and thirty-six thousand | eight thousand | one thousand | one hundred and fifty | 》90% | thirty | twelve | 2.2x2+0.55 |
WMH25 | one million and forty-five thousand | nine thousand | one thousand and two hundred | one hundred and fifty | 》90% | thirty-six | fourteen | 3x2+0.55 |
WMH30 | one million two hundred and fifty-five thousand | ten thousand | one thousand and four hundred | one hundred and fifty | 》90% | forty-two | sixteen | 3x2+0.55 |
Note:oneIn addition to the commonly used specifications mentioned above, larger models of hot air stoves can also be produced.
twoTheWMHThe air volume of the hot air stove is the output air volume of the dual fan hot air stove.
threeThe rated coal consumption refers to the theoretical amount of coal required to reach the rated heat generation.
fourThe experience of coal consumption refers to the use of standardized insulation, raising commercial chickens, rice husks for flat farming, and outdoors-15Celsius degrees1-3The chick rearing area has reachedthirty-fivecentigrade. Breeding periodforty-fiveHourly average coal consumption of the entire batch of chickens in the sky
Copyright © 2022 Linqu Weiyang Machinery & Equipment Factory All Rights Reserved
Record Number:鲁ICP备11024990号-1